« Evaporation zone » : différence entre les versions
Aller à la navigation
Aller à la recherche
(Création de la page) |
(Ajout partie sur les différents masques) |
||
(4 versions intermédiaires par le même utilisateur non affichées) | |||
Ligne 1 : | Ligne 1 : | ||
[[fr:Zone évaporation]] |
[[fr:Zone évaporation]] |
||
<p><strong>Head:</strong> |
<p><strong>Head:</strong> Daniel MATHIOT, [[People|Contact]]</p> |
||
⚫ | |||
<p><em>Sorry but there is no available English translation for this section at the moment, the following text is therefore in French.</em></p> |
|||
<br/> |
<br/> |
||
<table border="0" cellpadding="5" cellspacing="1" style="width: 100%;"> |
<table border="0" cellpadding="5" cellspacing="1" style="width: 100%;"> |
||
<tr><td><p>The evaporation zone of the glove boxes system contains a Joule effect evaporator. The material to be deposited is placed in a crucible that is warmed until evaporation of the material which is then deposited on the substrate.</p> |
|||
<tr><td><p>La zone évaporation du système de boîtes à gants contient un évaporateur à effet Joule. Le matériau à déposer est placé dans un creuset qui est chauffé jusqu'à évaporation du matériau et il se dépose alors sur le substrat.</p> |
|||
<p>Like most of the equipments of the platform, the evaporator is included in a service activity open to other laboratories and to companies. Applications can be simply sent by e-mail.</p> |
|||
<p>Comme la plupart des équipements de la plate-forme, l'évaporateur fait l’objet d’une activité de service ouverte aux autres laboratoires et aux entreprises. Les demandes peuvent simplement être adressées par courriel.</p> |
|||
<p><strong> |
<p><strong> Technical characteristics</strong></p> |
||
<ul><li> |
<ul><li>Brand Kurt J. Lesker, model Mini-Spectros</li> |
||
<li>Sources |
<li>Sources:</li> |
||
<ul><li>2 |
<ul><li>2 crucibles for metals (Al, Ag, MoO<sub>3</sub>, LiF, Ca, Ni, Au...)</li> |
||
<li>1 |
<li>1 Knudsen cell for organic materials</li></ul> |
||
<li> |
<li>Deposition thickness: variable depending on the deposited material, checked by a quartz balance</li> |
||
<li> |
<li>Size of the samples: 20 mm wide</li> |
||
<li> |
<li>Maximal number of samples: 9</li> |
||
<li> |
<li>Vacuum before deposition: up to 10<sup>-7</sup> mbar</li> |
||
<li> |
<li>Vacuum during deposition: 2-6·10<sup>-6</sup> mbar</li></ul></td> |
||
<td>[[Image:Evaporateur1Red2.jpg|right|200px| |
<td>[[Image:Evaporateur1Red2.jpg|right|200px|Evaporator of the glove box]]</td></tr></table> |
||
<table border="0" cellpadding="5" cellspacing="1" style="width: 100%;"> |
<table border="0" cellpadding="5" cellspacing="1" style="width: 100%;"> |
||
<tr><td>[[Image:PorteEchantillons2Red.jpg|center|200px| |
<tr><td>[[Image:PorteEchantillons2Red.jpg|center|200px|Sample holder for the evaporator of the glove box]]</td> |
||
<td><p><strong> |
<td><p><strong>Main uses</strong></p> |
||
<ul><li> |
<ul><li>metallic contacts</li> |
||
<li> |
<li>inorganic buffer layers </li> |
||
<li> |
<li>layers of small organic molecules</li> |
||
<li> ...</li></ul></td></tr></table> |
<li> ...</li></ul></td></tr></table> |
||
⚫ | |||
<p><strong>Masks</strong></p> |
|||
<p>Depending on needs, different types of masks can be conceived and realised by laser cutting (resolution 150 µm).</p> |
|||
<table border="0" cellpadding="5" cellspacing="1" style="width: 100%;"> |
|||
<tr><td>[[Image:Masque1.jpg|x150px|Masks solar cells]]</td> |
|||
<td>[[Image:Masque2.jpg|x150px|Masks Fraunhofer transistors]]</td> |
|||
<td>[[Image:Masque3.jpg|x150px|Masks drifted contacts for 4 tips measurements]]</td> |
|||
<td>[[Image:Masque4.jpg|x150px|Masks transistors of differente sizes]]</td></tr></table> |
Dernière version du 25 août 2016 à 08:23
Head: Daniel MATHIOT, Contact
The evaporation zone of the glove boxes system contains a Joule effect evaporator. The material to be deposited is placed in a crucible that is warmed until evaporation of the material which is then deposited on the substrate. Like most of the equipments of the platform, the evaporator is included in a service activity open to other laboratories and to companies. Applications can be simply sent by e-mail. Technical characteristics
|
Main uses
|
Masks
Depending on needs, different types of masks can be conceived and realised by laser cutting (resolution 150 µm).